A footing fails by moving, not by breaking. The wall it carries follows it, and the first anyone knows is a door that sticks in March and swings free in September. The cause is a footing dug to the code minimum of 12 inches, which on most lots here leaves it sitting in the sand above the clay, lifted and dropped by every wet winter. Dig it to bear on the clay, tie a bar along the top and the bottom for its whole length, and the wall on it stays where it was built.
Harbor Fullerton Concrete was started in 2021 by Grant Yoshida, who spent 14 years on Orange County foundation crews first, and he is in the trench for every inspection. Most footings we pour are for additions and accessory units on postwar lots, along with block fence walls, patio cover posts and the wall that fills an old garage door when the garage becomes a dwelling. That last one catches people out, because the slab at the door is a thin apron with nothing under it.
Footings are built to the California Residential Code under a CSLB C-8 concrete license, with liability insurance on every job, and in this seismic category a continuous footing carries a bar along the top and the bottom. Building and Safety inspects the trench open before concrete is ordered, and where a soils report calls for more depth or a pier we build to the report. Every footing carries a written workmanship guarantee against defects in how it was built.